Publication: Salivary D-dimer in pigs: Validation of an automated assay and changes after acute stress
Authors
López Martínez, M. J. ; Escribano, D. ; Contreras Aguilar, M. D. ; García Martínez, Juan Diego ; Martínez Subiela, S. ; Cerón, J. J.
item.page.secondaryauthor
item.page.director
Publisher
Elsevier
publication.page.editor
publication.page.department
DOI
https://doi.org/10.1016/j.tvjl.2020.105472
item.page.type
info:eu-repo/semantics/article
Description
© 2020 Elsevier Ltd. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
This document is the Published version of a Published Work that appeared in final form in The Veterinary Journal . To access the final edited and published work see https://doi.org/10.1016/j.tvjl.2020.105472
Abstract
D-dimer is a peptide found in serum and is derived from the degradation of blood clots. Even though it has been analysed in human saliva, D-dimer has not been previously evaluated in the saliva of any veterinary species, and its source and role remain unknown. The objectives of this research were firstly, to validate the use of an automated method for the measurement of D-dimer in porcine saliva, and secondly, to evaluate whether D-dimer concentration changes in pig saliva after an acute stress stimulus. For this purpose, a complete analytical validation of a commercially-available immunoturbidimetric assay was carried out. In addition, an experimental acute stress model was induced in 11 pigs based on a technique involving restraint by nose-snare immobilisation for 1 min. Saliva samples were subsequently collected at different times and D-dimer, salivary alpha-amylase (sAA) and cortisol were assessed in order to evaluate changes in its concentrations after the stress induction.
The D-dimer automated assay showed adequate reproducibility and sensitivity, with coefficients of variation below 10% and a limit of quantification of 0.167 μg/mL fibrinogen equivalent units (FEU). It also showed a high accuracy, determined by linearity under dilution and recovery tests. In the stress model, a significant increase (P < 0.05) in salivary D-dimer 15 min after the stress stimulus and a positive correlation between D-dimer and sAA (r = 0.51; P < 0.001) were observed. These results indicate that D-dimer can be measured in porcine saliva with an automated method and suggest that its concentration can be influenced by stressful conditions.
Citation
The Veterinary Journal, 2020, Vol. 259–260 : 105472
item.page.embargo
Collections
Ir a Estadísticas
Sin licencia Creative Commons.