Repository logo
  • English
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Latviešu
  • Magyar
  • Nederlands
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Log In
    or
    New user? Click here to register.
Repository logo

Repositorio Institucional de la Universidad de Murcia

Repository logoRepository logo
  • Communities & Collections
  • All of DSpace
  • Statistics
  • menu.section.collectors
  • menu.section.acerca
  • English
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Latviešu
  • Magyar
  • Nederlands
  • Português
  • Português do Brasil
  • Suomi
  • Svenska
  • Türkçe
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Log In
    or
    New user? Click here to register.
  1. Home
  2. Browse by Subject

Browsing by Subject "Ultrasonography"

Now showing 1 - 11 of 11
Results Per Page
Sort Options
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Efectividad de la ultrasonografía en la punción venosa periférica: revisión integradora
    (Universidad de Murcia, 2016) Reichembach Danski, Mitzy Tannia; Maciel de Oliveira, Andrey; Meier, Marineli Joaquim; Pedrolo, Edivane
    Objetivo: Identificar las evidencias producidas en la literatura sobre la efectividad de la ultrasonografía para el éxito en la punción venosa con relación al método tradicional de punción. Método: Se realizó una revisión integradora de literatura en las bases de datos Lilacs y PubMed, en el período de enero de 2009 a febrero de 2015. Fueron incluidas publicaciones en portugués, inglés o español, que contemplaron los objetivos y/o el tema de la investigación en el título o resumen y que utilizaron revisiones sistemáticas, ensayos clínicos o estudios observacionales como metodología. Resultados: Compuesto por 16 artículos, con alto nivel de evidencia, que refuerzan la efectividad de la ultrasonografía para la punción venosa periférica difícil. Hubo reducción del número de intentos de punción cuando se usó la ultrasonografía. La tasa de éxito con el uso de la ultrasonografía quedó entre 70% y 99% y varió de acuerdo con características demográficas (sexo, edad y color de la piel), clínicas (diámetro y profundidad de la vena) y operacionales (elección del catéter y habilidad del profesional que realiza el procedimiento). Conclusión: La ultrasonografía puede aumentar el éxito de este procedimiento, pero es necesario obtener más evidencias sobre el tiempo gastado y el número de intentos para lograr el éxito. La habilidad del operador del equipo ultrasonográfico, así como las características clínicas, técnicas y operacionales se revelaron como factores importantes que deben ser tenidos en cuenta para una punción venosa más efectiva y segura.
  • Loading...
    Thumbnail Image
    Publication
    Embargo
    Estudio ecográfico morfológico muscular en profesionales de danza
    (Universidad de Murcia, 2024-11-15) Alcocer Ojeda, Miguel Ángel; Gómez Conesa, Antonia; Escuela Internacional de Doctorado
    Introducción: El dolor inguinal (DI) relacionado con la cadera está presente en la danza, con una incidencia de lesiones del 17,7%, contribuyendo al 14,1% de las lesiones en estudiantes, y al 27,6 en bailarines profesionales. Así mismo, en los bailarines profesionales, la tasa de lesiones se sitúa entre 1,06 y 1,46 por cada 1.000 horas de danza, con mayor afectación en las extremidades inferiores. En atletas con DI, se ha encontrado disminución del grosor de los músculos abdominales y de la cadera, y hasta donde sabemos, ningún estudio ha examinado los cambios en el grosor de estos músculos en bailarines con y sin DI. Objetivo: Evaluar, mediante Rehabilitative Ultrasound Imaging (RUSI), el grosor de los músculos abdominales, multífidos lumbares, glúteo medio (GM) y glúteo menor (GMN) en profesionales de una compañía de danza y con el fin de determinar la posible relación entre los cambios neuromusculares ecográficos detectados, con diversas variables clínicas y pruebas funcionales de cadera, y su implicación en el desarrollo de DI. Metodología: De una muestra de 33 bailarines profesionales de danza del Ballet Nacional de España, 20 cumplimentaron el cuestionario Copenhagen Hip And Groin Outcome Score (HAGOS) y una entrevista con datos sociodemográficos y clínicos. Posteriormente se midió el grosor de los músculos abdominales, multífidos lumbares, glúteo mediano (GM) y glúteo menor (GMN), mediante metodología RUSI, y se les realizó la prueba de laxitud articular de Beighton. Todos estos valores se analizaron con el fin de calcular las correlaciones entre las variables utilizando el coeficiente de correlación de Spearman (r), con un nivel de confianza del 95% y un nivel de significancia de 0,05. Resultados: La puntuación de HAGOS correlacionó negativamente con la edad (-0,61) y con el número de años de práctica de danza (-0,70). La correlación entre la escala de Beighton y el valor de HAGOS fue de 0,20. La correlación entre el HAGOS y el grosor muscular del GM derecho activo fue de 0,46, mientras que para el GM izquierdo activo fue de 0,40 y en reposo de 0,44. La correlación entre la puntuación de Beighton con el grosor muscular fue elevado con oblicuo interno izquierdo en reposo (-0,50) y activo (-0,48), el transverso activo, tanto izquierdo (-0,52) como derecho (-0,56), el recto anterior derecho en reposo (-0,55), y el GMN derecho en reposo (-0,51). Conclusiones: A mayor edad y más años practicando danza, existe mayor probabilidad de padecer DI. Por el contrario, la hiperlaxitud articular no guarda correlación con el DI relacionado con la cadera. A menor grosor muscular, mayor laxitud articular. El grosor del músculo GM activo bilateral y del GM izquierdo en reposo correlaciona positivamente con el DI relacionado con la cadera y puede ser un predictor de trastornos de cadera o ingle en profesionales de Ballet. Registrado en ClinicalTrials.gov (NCT05654168), y aprobado por el Comité de Ética de Investigación de la Universidad de Murcia 2585/2019.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Infrared thermography, intratendon vascular resistance and echotexture in athletes with patellar tendinopathy: a cross-sectional study
    (SAGE Publications, 2023-03) Molina Payá, Francisco J.; Ríos Díaz, José; Carrasco Martínez, Francisco; Martínez Payá, Jacinto Javier; Fisioterapia
    Background: Ultrasonographic signs of tendinopathies are an increase in thickness, loss of alignment in collagen fibers and the presence of neovascularization. Nevertheless, analysis of intratendinous vascular resistance (IVR) can be more useful for understanding the physiological state of the tissue. Objective: To show thermal, echotextural and Doppler signal differences in athletes with patellar tendinopathy and controls. Methods: Twenty-six athletes with patellar tendinopathy (PT) participants (30.1 yrs; SD= 9.0 yrs) and 27 asymptomatic athletes (23.3 yrs; SD= 5.38 yrs) were evaluated with thermographic and Doppler ultrasonography (DS). Area of Doppler signals (DS), echotextural parameters (echointensity and echovariation) and IVR were determined by image analysis. The statistical analysis was performed by Bayesian methods and the results were showed by Bayes Factor (BF10: probability of alternative hypothesis over null hypothesis), and Credibility intervals (CrI) of the effect. Results: The absolute differences of temperature (TD) were clearly greater (BF10= 19) in the tendinopathy group (patients) than in controls. Regarding temperature differences between the affected and healthy limb, strong evidence was found (BF10= 14) for a higher temperature (effect= 0.53 ºC; 95% CrI=0.15 to 0.95 ºC) and very strong for reduced IVR compared (BF10= 71) (effect= -0.67; 95% CrI=- 1.10 to -0.25). The differences in area of DS (BF10= 266) and EV (BF10= 266) were higher in tendinopathy group. TD showed a moderate positive correlation with VISA-P scores (tau-B=.29; 95% CrI=.04 to .51) and strong correlation with IVR (r=-.553; 95%CrI=-.75 to -.18). Conclusion: Athletes with patellar tendinopathy showed a more pronounced thermal difference, a larger area of Doppler signal, a lower IVR and a moderately higher echovariaton than controls. The correlation between temperature changes and IVR might be related with the coexistence of degenerative and inflammatory process in PT.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Presente y futuro del diagnóstico de gestación en el ganado bovino
    (Universidad de Murcia. Servicio de publicaciones, 2022) Sice, Margaux; Gómez Martín, Ángel; Gomis Almendro, Jesús
    Para llevar a cabo el diagnóstico de gestación en el ganado bovino, se debe utilizar un método preciso, seguro, económico y que se pueda realizar de manera temprana. Aunque varias técnicas están actualmente disponibles en el mercado, otras siguen todavía en desarrollo, siendo posibles herramientas diagnósticas a tener en cuenta en un futuro. Por ello, el presente trabajo tiene como objetivo hacer una revisión sobre las diversas técnicas de diagnóstico de gestación (DG) y su potencial uso a nivel comercial, tanto en el presente como en el futuro, de la ganadería bovina. Los métodos directos para el DG, como son la palpación directa o la ecografía del tracto reproductor vía transrectal, siguen siendo los más empleados en la actualidad durante el control gestacional en el ganado vacuno. Son técnicas diagnósticas con buenos resultados y son interesantes a nivel económico, pero son herramientas invasivas y requieren una cierta experiencia por parte del técnico que las realiza. En general, se aplican a partir de la 3ª-4ª semana posterior a la inseminación artificial. Por otro lado, los métodos indirectos de DG son menos invasivos que los directos. Mediante este tipo de diagnósticos vía indirecta se puede detectar la presencia o ausencia de un embrión, sin visualizar directamente estructuras gestacionales. Existen métodos indirectos basados en signos clínicos, como la vigilancia del retorno al estro, así como técnicas indirectas bioquímicas, que permiten evaluar mediante el uso de kits rápidos ciertas sustancias como la progesterona (P4) o las Glicoproteínas Asociadas a la Gestación (GPAG), producidas durante la gestación de forma temprana. Otras técnicas novedosas y prometedoras, pero que todavía se encuentran en desarrollo, sonla evaluación de moléculas como el interferón tau (IFNτ), los micro-ARN (miARN) y/o los Factores de Gestación Temprana (FGT).
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Protocolo de ecografía para diagnóstico precoz del desprendimiento de retina
    (Universidad de Murcia, 2025-05-30) Felices Farias, Jose Manuel; Guzmán Aroca, Florentina; Puerta Sales, Alejandro; Santa-Olalla González, Manuel; Escuela Internacional de Doctorado; Escuela Internacional de Doctorado
    El desprendimiento de retina (DR) es una emergencia en la que el diagnóstico precoz resulta fundamental para prevenir la pérdida irreversible de la visión. Sin embargo, en presencia de opacidad de los medios, la evaluación del fondo de ojo puede verse limitada, de modo que la ecografía oftálmica se convierte en la principal alternativa diagnóstica para una valoración temprana. El objetivo de este estudio fue determinar el rendimiento del protocolo Arrixaca, que evalúa los principales hallazgos ecográficos para el diagnóstico diferencial del DR frente a otras patologías de apariencia similar como el desprendimiento de vítreo posterior (DVP) o el hemovítreo (HV). Se realizó un estudio observacional prospectivo en 127 pacientes con indicación de ecografía oftálmica por sospecha de DR. El examen se realizó utilizando el protocolo Arrixaca, aplicado por tres radiólogos con distintos años de experiencia. Se comparó la precisión diagnóstica con el gold standard (fondo de ojo o hallazgos quirúrgicos según la indicación clínica) y la concordancia interobservador entre los tres radiólogos. Los resultados mostraron que el protocolo Arrixaca consiguió un excelente rendimiento con un muy alto porcentaje de acierto, superior tanto al protocolo UM como a los resultados registrados en publicaciones previas, incluso en condiciones de opacidad de medios. Este análisis destaca especialmente al protocolo Arrixaca por su capacidad de minimizar los falsos negativos, un aspecto crítico para proteger la visión del paciente. Además, la concordancia entre los tres radiólogos fue muy elevada, por lo que el protocolo Arrixaca reveló ser altamente reproducible y sencillo. En conjunto, los hallazgos confirman que la ecografía oftálmica con el protocolo Arrixaca es una alternativa eficaz y accesible para el diagnóstico de DR, aún en pacientes con opacidad de medios. Su incorporación en los servicios de Radiología podría optimizar la detección precoz del DR y mejorar el pronóstico visual de los pacientes.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Quantitative neuromuscular ultrasound analysis as biomarkers in amyotrophic lateral sclerosis
    (2019-08) Martínez Payá, Jacinto Javier; Vázquez-Costa, Juan F.; Chumillas, Maria J.; Tembl Ferrairó, José I.; Baño Aledo, María Elena del; Ríos Díaz, José; Fisioterapia
    Objectives: To assess the differences in morphological and texture parameters of median nerve (MN) and abductor pollicis brevis (APB) between amyotrophic lateral sclerosis (ALS) patients and controls. Methods: The cross-sectional area (CSA) of the MN and the muscle thickness (MTh) of APB were measured bilaterally in 59 recently diagnosed ALS patients and 20 matched healthy controls. Echointensity (EI), echovariation (EV) and grey-level co-occurrence matrix (GLCM) texture features of both structures were also analysed. Correlations between these parameters and clinical variables (muscle strength and disability) were analysed. Results: The CSA of MN was significantly lower in ALS patients (MD = - 1.83 mm2 [95% CI = 2.89; - 0.77 mm2]; p = 0.01). ALS patients showed significantly lower MTh (- 2.23 mm [3.16; - 1.30 mm]; p < 0.001) and EV (- 7.40 [11.5; - 3.33]; p = 0.004) and higher EI (21.2 [11.9; 30.6]; p < 0.001) in the APB muscle. No relevant differences were detected in GLCM features for this muscle. The model including all parameters (CSA for MN and MTh, EI and EV for APB) showed an AUC of 82% (sensitivity 87%; specificity 42%). Muscle strength and disability correlated with APB muscle ultrasound parameters but not with those of the MN. Conclusions: APB muscle ultrasound biomarkers (especially MTh and EI) showed better discrimination capacity and correlation with clinical variables than MN biomarkers. However, the combination of both biomarkers increased their ability to detect LMN impairment, suggesting that both biomarkers could be used in a complementary manner for the diagnosis and progression monitoring in ALS.
  • Loading...
    Thumbnail Image
    Publication
    Restricted
    Relationship between jumping abilities and skeletal muscle architecture of lower limbs in humans: systematic review and meta-analysis
    (Elsevier, ) Ruiz Cárdenas, J. D.; Rodríguez Juan, Juan José; Ríos Díaz, J.; Fisioterapia
    The aim of this study was to examine the influence of skeletal muscle architecture (SMA) features measured by 2-D ultrasonography on jumping performance in humans. A systematic review and meta-analysis was conducted, registry number: CRD42016043602. The scientific literature was systematically searched in eight databases, last run on March 14th, 2017. Cross-sectional studies focused on the association between SMA features and vertical jumping performance were selected. A random-effects model was used to analyze the influence of lower-limb SMA and maximal jump height. A total of 11 studies were included in the qualitative synthesis and 6 studies were selected for meta-analysis. 250 correlations were reviewed across studies. The vast majority were either not statistically significant (185; 74%), weak or very weak (169; 68%) for different jump modalities; counter-movement jump (CMJ), squat jump (SJ), and drop jump. There was insufficient data to perform meta-analysis on muscles other than vastus lateralis for CMJ and SJ. The meta-analyses did not yield any significant association between vastus lateralis SMA and SJ height. Only a significant overall association was shown between vastus lateralis thickness and CMJ height (summary-r = 0.28; 95% confidence interval (CI) = −0.05 to 0.48; p = .059) for a 90% CI level. No differences were found between summary-r coefficients for SMA parameters and jump height during both jumps (CMJ: χ2 = 2.43; df   = 2; p = .30; SJ: χ2 = 0.45; df = 2; p = .80) with a low heterogeneity ratio. Current evidence does not suggest a great influence of lower-limb SMA on vertical jumping performance in humans.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Respuesta a la estimulación ovárica mediante FSH (folltropin®) y rendimiento de opu en vacas adultas obtenidas por diferentes técnicas de reproducción asistida
    (Universidad de Murcia. Servicio de publicaciones, 2022-11-15) Morera Jiménez, Alba; Velasco García, Elena; Ruiz López, Salvador; Romero Aguirregomezcorta, Jon; Anatomía y Anatomía Patológica Comparadas
    Los objetivos de este trabajo han sido realizar un seguimiento ecográfico de los ovarios bovinos para comprobar la respuesta folicular de vacas adultas nacidas por diferentes técnicas de reproducción asistida (TRA), tras aplicar un protocolo de estimulación ovárica con FSH (Folltropin®); y determinar la eficacia reproductiva de los animales estudiados, analizando la cantidad y calidad de los ovocitos obtenidos por aspiración folicular (Ovum Pick-Up, OPU) antes y después del protocolo de estimulación empleado. La experiencia se ha llevado a cabo en las instalaciones del santuario bovino de la Granja Docente Veterinaria de la Universidad de Murcia. Se han utilizado 4 hembras bovinas obtenidas por distintas TRA: inseminación artificial (IA), transferencia de embriones (TE) producidos por TRA con ovocitos cultivados in vitro en medios convencionales y por TE obtenidos por TRA con ovocitos cultivados con fluidos naturales (folicular y oviductal).Los animales fueron estimulados durante 5 semanas mediante un protocolo que consistía en la aplicación de GnRH y posteriormente, FSH (Folltropin®, 350 UI/animal) durante 3 días en dosis decrecientes. Una vez a la semana, al finalizar el protocolo de estimulación ovárica, se realizaba una ecografía de los ovarios y una aspiración folicular ecoguiada (OPU) para comprobar la respuesta al protocolo de estimulación y determinar el número de folículos y de ovocitos obtenidos tras la OPU y su calidad ovocitaria. Previamente al periodo de estimulación con FSH, las vacas fueron ecografiadas y sometidas a OPU 3 semanas sin estimulación ovárica como grupo control.A lo largo del trabajo realizado, se ha comprobado la respuesta al protocolo de estimulación ovárica ensa-yado, y se ha determinado la eficacia reproductiva de los animales, según el número de folículos aspirados y la cantidad y calidad de los ovocitos obtenidos por OPU en cada una de ellas.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Sonoelastography for the Assessment of Muscle Changes in Amyotrophic Lateral Sclerosis: Results of a Pilot Study
    (Elsevier, 2018) Martínez Payá, Jacinto Javier; Baño Aledo, María Elena del; Ríos Díaz, José; Fornés Ferrer, Victoria; Vázquez Costa, Juan F.; Fisioterapia
    The purpose of this study was to assess the sonoelastographic features of four different muscles in patients with amyotrophic lateral sclerosis compared with healthy controls and to evaluate the relationship of these features to muscle strength and other ultrasonographic variables. Fourteen patients with amyotrophic lateral sclerosis and 20 controls were examined using strain sonoelastography scanning. The RGB channel fraction ratio was analyzed with ImageJ software (Version 1.48). Two main sonoelastographic patterns could be distinguished in the controls: a clear predominance of the blue channel (hard areas) and a more heterogeneous pattern with predominance of the green channel (intermediate stiffness). These patterns were also observed in patients, although a higher green channel score was observed in mildly impaired muscles, whereas a higher blue channel score was observed in the most severely impaired muscle. Sonoelastography may be a good complementary biomarker in the detection and monitoring of muscle changes in amyotrophic lateral sclerosis.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Testicular ultrasound patterns, sperm quality, seminal microbiota, caprine arthritis encephalitis virus and Coxiella burnetii infection in bucks
    (Elsevier, 2026-04-25) Bailón-Larrañaga, N.; Gomis, J.; Contreras de Vera, Antonio; Toledo-Perona, R.; Toquet, M.; Reyes, L.E.; Quereda, J.J.; Gonzalez-Torres, P.; Gñpmez-Marín, A.; Sanidad Animal
    This study assesses the frequency and severity of ultrasound-detected testicular alterations across age groups (young and adult) in 219 bucks. Sperm quality and testicular echotexture were evaluated, and their associations with reproductive pathogens (Coxiella (C.) burnetii, caprine arthritis encephalitis virus (CAEV), Chlamydia (C.) abortus and Mycoplasma (M.) agalactiae) were analyzed. Additionally, qPCR was also performed on ejaculates from seropositive bucks. Seminal microbiota was characterized in three groups: 1 (seronegative without lithiasis), 2 (seropositive with lithiasis), and 3 (qPCR-CAEV-positive). A 68.5% of bucks showed testicular microlithiasis (50.2% bilateral and 18.2% unilateral). Moreover, frequency of bilateral lesions differed according to age, being higher in adults, who also showed larger microlithiasis area (P < 0.05). Age was negatively correlated with sperm concentration (P < 0.05). Seropositivity was 35.8% for C. burnetii and 58.8% for CAEV. Adults showed higher CAEV seropositivity (P < 0.001), and 4.2% of ejaculates tested qPCR positive for this pathogen. Bacterial richness was greater (P < 0.001) in group 2 than in group 1. Firmicutes dominated groups 1 and 2, whereas Fusobacteriota prevailed in group 3. The most frequent genus in all three experimental groups was Oceanivirga, with higher abundance in group 1 than in group 2 (P < 0.05). These findings suggest that ejaculate microbiota may be influenced by ultrasound abnormalities and exposure to CAEV and C. burnetii, supporting the use of testicular ultrasound to detect bucks prone to reproductive problems and associated health risks, while also highlighting the need to include males in CAE and Q fever control programs.
  • Loading...
    Thumbnail Image
    Publication
    Open Access
    Valoración del flujo arterial del cordón umbilical en fetos caprinos de raza murciano-granadina mediante ecografía doppler espectral
    (Universidad de Murcia. Servicio de publicaciones, 2022) Martínez Díaz, Sandra; García Vázquez, Francisco Alberto; Luongo, Chiara; Ruiz López, Salvador
    La raza Murciano-Granadina (M-G) es considerada la raza caprina más representativa de España y su sistema productivo presenta una elevada trascendencia. La ecografía ha demostrado ser un procedimiento de gran utilidad en reproducción animal para la detección y seguimiento de la gestación y la ecografía Doppler ha posibilitado obtener mediciones objetivas no invasivas del aporte vascular y la funcionalidad de diversos órganos y estructuras. El objetivo de este trabajo ha sido la evaluación de las características hemodinámicas de la arteria umbili-cal en fetos caprinos de raza M-G empleando parámetros e índices Doppler para valorar la aplicabilidad de la ecografía Doppler en la evaluación de la vascularización fetal.El estudio se llevó a cabo en 4 cabras gestantes M-G, pertenecientes al IMIDA, ubicadas en la Granja Do-cente Veterinaria. Los exámenes y mediciones de los parámetros Doppler en la arteria umbilical se llevaron a cabo una vez por semana entre los días 75 y 120 de gestación, suponiendo un total de 5 a 7 sesiones ecográficas en cada hembra. Se analizaron los siguientes parámetrosDoppler: velocidad sistólica máxima (PSV), velocidad diastólica final (EDV), velocidad media (VM), índice de resistividad (IR), índice de pulsatilidad (IP) y relación sístole/diástole (S/D) además, del pulso de la arteria umbilical (PA). PSV y VM se mantuvieron con valores similares, sin diferen-cias significativas, mientras que EDV aumentó con diferencias significativas en el periodo gestacional analizado. Los valores de IR, IP y S/D descendieron de forma continua y significativa. Los valores de PA variaron de forma significativa durante la gestación, alcanzado su máximo en el día 90 y llegando a su valor mínimo el día 120. Los índices Doppler ofrecen gran precisión y pueden utilizarse con éxito para estudiar la perfusión sanguínea y los parámetros velocimétricos del cordón umbilical en fetos durante el periodo de gestación en cabras M-G

DSpace software copyright © 2002-2026 LYRASIS

  • Cookie settings
  • Accessibility
  • Send Feedback