Publication:
Interobserver agreement for thyroid elastography. Value of the quality factor

dc.contributor.authorCepero Calvete, Angela
dc.contributor.authorRodriguez, José Manuel
dc.contributor.authorBerná Mestre, Juan de Dios
dc.contributor.authorRios, Antonio
dc.contributor.authorAbellán Rivero, Delores
dc.contributor.authorReus Pintado, Manuel
dc.contributor.departmentDermatología, Estomatología, Radiología y Medicina Física
dc.date.accessioned2025-01-17T09:37:15Z
dc.date.available2025-01-17T09:37:15Z
dc.date.issued2013-03-01
dc.description© 2013 by the American Institute of Ultrasound in Medicine. This document is the Published Manuscript version of a Published Work that appeared in final form in Journal of Ultrasound in Medicine. To access the final edited and published work see https://doi.org/10.7863/jum.2013.32.3.495
dc.description.abstractObjectives—The purpose of our study was to investigate interobserver agreement for thyroid ultrasound elastography and to analyze the reproducibility of real-time free hand elastography in thyroid nodules. Methods—A prospective nonrandomized double-blind study was conducted between September 2008 and June 2010. Real-time elastography of 89 thyroid nodules was performed by two radiologists, with the first radiologist evaluating each thyroid nodule 5 minutes before the second. The elastograms were obtained with the patients holding their breath and considered valid when the quality factor was 50 or higher. The region of interest was positioned to include the nodule and 0.5 cm of surrounding normal thyroid parenchyma but to exclude the carotids and esophageal-tracheal structures. The elastograms were classified on a scale of 5 different patterns. Results—Observers 1 and 2 coincided in 79 elastographic patterns and disagreed on 10 nodules (11.2%). The results between the radiologists had a statistically significant agreement (P < .005), with a κ value of 0.838. Conclusions—The introduction of a quality factor in elastographic software and the selection of elastograms with a quality factor of 50 or higher confer almost perfect interobserver agreement for thyroid nodule elastography and make elastography a reproducible technique that could be used in daily clinical practice.es
dc.formatapplication/pdfes
dc.format.extent10es
dc.identifier.citationJournal of Ultrasound in Medicine, 2013, Vol. 32, Issue 3, pp. 381-550
dc.identifier.doihttps://doi.org/10.7863/jum.2013.32.3.495
dc.identifier.issnPrint: 0278-4297
dc.identifier.issnElectronic: 1550-9613
dc.identifier.urihttp://hdl.handle.net/10201/148649
dc.languageenges
dc.publisherWileyes
dc.relationSin financiación externa a la Universidades
dc.relation.publisherversionhttps://onlinelibrary.wiley.com/doi/10.7863/jum.2013.32.3.495
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectThyroides
dc.subjectThyroid canceres
dc.subjectUltrasound (US)es
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicina::615 - Farmacología. Terapéutica. Toxicología. Radiologíaes
dc.titleInterobserver agreement for thyroid elastography. Value of the quality factores
dc.typeinfo:eu-repo/semantics/articlees
dspace.entity.typePublicationes
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
3-JUM Elasto 2013.pdf
Size:
335.78 KB
Format:
Adobe Portable Document Format
Description:
Elasto Cualitativa Tiroides
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.26 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections