Publication:
Real-time potentiometric monitoring of tetrachloroaurate(III) with an Ion-selective electrode and its applications to HAuCl4 iodide-catalyzed reduction by hydroxylamine

dc.contributor.authorAlmagro Gómez, Carmen M.
dc.contributor.authorHernández Cifre, José G.
dc.contributor.authorOrtuño Sánchez-Pedreño, Joaquín A.
dc.contributor.departmentQuímica Física
dc.date.accessioned2025-01-21T07:53:01Z
dc.date.available2025-01-21T07:53:01Z
dc.date.issued2024-06-01
dc.description© 2024 by the authors. This manuscript version is made available under the CC-BY 4.0 license http://creativecommons.org/licenses/by/4.0/ This document is the Published Manuscript version of a Published Work that appeared in final form in Chemosensors. To access the final edited and published work see https://doi.org/10.3390/chemosensors12060095
dc.description.abstractIon-selective electrodes for tetrachloroaurate(III) have been developed for potentiometric monitoring of the reduction reaction of tetrachloroaurate(III). Three different plasticized polyvinyl chloride membranes containing tridodecymethylammonium chloride as an anion exchanger were investigated. These membranes differ in the plasticizer used, either 2-nitrophenyl octyl ether (NPOE) or tricresyl phosphate (TCP) or bis-(2-ethylhexyl) sebacate (DOS). The potentiometric response of the electrodes to the tetrachloroaurate(III) concentration was studied by two methods. In the first method, commonly used in the calibration of ion-selective electrodes, successive tetrachloroaurate(III) concentration increments were used and the potential was allowed to stabilize after each concentration step. The second method was developed to mimic the tetrachloroaurate(III) reduction reaction in which there is a continuous decrease in the concentration of tetrachloroaurate(III). This was achieved by continuously diluting an initial concentration of tetrachloroaurate(III) by pumping a diluent solution while keeping the sample volume constant. This method gave an excellent linear response to the tetrachloroaurate(III) concentration. The calibrated electrodes were used for the potentiometric monitoring of the kinetics of a newly observed reaction: the reduction of tetrachloroaurate(III) by hydroxylamine catalyzed by iodide. A mechanism for this reaction is proposed on the basis of the experimental results obtained.es
dc.formatapplication/pdfes
dc.format.extent12es
dc.identifier.citationChemosensors, 2024, Vol. 12 (6) : 95
dc.identifier.doihttps://doi.org/10.3390/chemosensors12060095
dc.identifier.issnElectronic: 2227-9040
dc.identifier.urihttp://hdl.handle.net/10201/148852
dc.languageenges
dc.publisherMDPIes
dc.relation1) Proyecto nacional PID2022-136568NB-I00, Ministerio de Ciencia e Innovación (MCIN/AEI/10.13039/501100011033), 2) Proyecto regional "Desarrollo de metodologías para la caracterización estructural de macromoléculas y nanopartículas en disolución. Aplicaciones a sistemas biológicos y materiales sintéticos", 20933/PI/18, Fundación Séneca (Agencia Regional para la Ciencia y la Tecnología de la Región de Murcia), 3) Proyecto nacional "Theory guided optimization of heterogeneous electrochemical reactions involved in electrical energy storage and conversion devices", TED2021-130334B-I00 (NextGenerationEU/PRTR), Ministerio de Ciencia, Innovación y Universidades.es
dc.relation.publisherversionhttps://www.mdpi.com/2227-9040/12/6/95es
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.subjectTetrachloroaurate IIIes
dc.subjectIon selective electrodeses
dc.subjectPotentiometric monitoringes
dc.subjectTetrachloroaurate III reductiones
dc.subject.otherCDU::5 - Ciencias puras y naturales::54 - Química::543 - Química analíticaes
dc.titleReal-time potentiometric monitoring of tetrachloroaurate(III) with an Ion-selective electrode and its applications to HAuCl4 iodide-catalyzed reduction by hydroxylaminees
dc.typeinfo:eu-repo/semantics/articlees
dspace.entity.typePublicationes
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
public71-Chemosensors24.pdf
Size:
2.94 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.26 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections