Publication:
Comparison of partial coherence interferometry and ultrasound for anterior segment biometry

dc.contributor.authorLara Lacárcel, Francisco
dc.contributor.authorFernández Sánchez, Vicente
dc.contributor.authorLópez Gil, Norberto
dc.contributor.authorCerviño, Alejandro
dc.contributor.authorMCOptom
dc.contributor.authorMontés Micó, Robert
dc.contributor.authorMPhil
dc.contributor.departmentOftalmología, Optometría, Otorrinolaringología y Anatomía Patológica
dc.date.accessioned2026-02-04T08:08:04Z
dc.date.available2026-02-04T08:08:04Z
dc.date.copyright© 2009 by Lippincott Williams & Wilkins, Inc.
dc.date.issued2009-02
dc.description.abstractPURPOSE: To assess the performance of a partial coherence interferometry (PCI)–based device for the determination of anterior segment biometry. SETTING: Clinica Centrofama, Cartagena, Murcia, Spain. METHODS: Central corneal thickness (CCT), anterior chamber depth (ACD), and lens thickness (LT) were measured with the ACMaster PCI anterior segment biometer and an Echoscan US-1800 ultrasound (US) biometer/pachymeter with and without cycloplegia. To determine the precision of the instruments, the same examiner took 30 consecutive CCT, ACD, and LT measurements in a single subject under the same conditions and with and without cycloplegia. The same measurements were performed in additional subjects. RESULTS: Twenty-one eyes (16 subjects) were evaluated. Repeated measurements of the single subject yielded a standard deviation of 4.0 mm for CCT, 106.0 mm for ACD, and 323.0 mm for LT; there were many peaks, mainly in the last 10 readings. There was a high correlation between CCT measurements with both systems with and without cycloplegia (r2>0.93), with the US system giving higher values. Differences were significant (P<.001), but not consistent, throughout the range of corneal thicknesses and were greater for thicker corneas. Differences in ACD and LT measurements were similar. Agreement between systems in ACD and LT measurements was considerably lower than for CCT measurements. CONCLUSIONS: The PCI biometer provided precise CCT measurements. The ACD and LT measurements had a higher variance. Differences in CCT measurements between the 2 systems were greater for thicker corneas, with higher values with the US system.
dc.formatapplication/pdf
dc.format.extent6
dc.identifier.citationJ Cataract Refract Surg . 2009 Feb;35(2):324-9
dc.identifier.doihttps://doi.org/10.1016/j.jcrs.2008.10.038
dc.identifier.eissn1873-4502
dc.identifier.issn0886-3350
dc.identifier.urihttp://hdl.handle.net/10201/198989
dc.languageeng
dc.publisherLippincott, Williams & Wilkins
dc.relationSin financiación externa a la Universidad
dc.relation.publisherversionhttps://journals.lww.com/jcrs/abstract/2009/02000/comparison_of_partial_coherence_interferometry_and.37.aspx
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess
dc.subject.odsObjetivo 3: Salud
dc.titleComparison of partial coherence interferometry and ultrasound for anterior segment biometry
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublicationes
relation.isAuthorOfPublication3005d113-09a9-4491-8709-a42cea552aa6
relation.isAuthorOfPublication20b1e4e9-3ce1-42dd-a0b1-44c2cf05e725
relation.isAuthorOfPublication.latestForDiscovery3005d113-09a9-4491-8709-a42cea552aa6
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Comparison of partial coherence interfermetry and ultrasound for anterior segment biometry.pdf
Size:
197.05 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.37 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections