Microleakage beneath brackets bonded with flowable materials: effect of thermocycling

dc.contributor.authorVicente Hernández, Ascensión
dc.contributor.authorOrtiz Ruiz, Antonio José
dc.contributor.authorBravo González, Luis Alberto
dc.contributor.departmentDermatología, Estomatología, Radiología y Medicina Física
dc.date.accessioned2024-06-26T08:37:41Z
dc.date.available2024-06-26T08:37:41Z
dc.date.issued2009-03-31
dc.description© The Author 2009. This document is the Published version of a Published Work that appeared in final form in European Journal of Orthodontics (EJO). To access the final edited and published work see https://doi.org/10.1093/ejo/cjn126
dc.description.abstractThe purpose of this study was to evaluate the effects of thermocycling on microleakage beneath brackets bonded with an orthodontic composite and different flowable materials. Brackets were bonded to 200 bovine incisors divided into five groups: (1) Transbond XT, (2) X-Flow, (3) Dyract-Flow, (4) Admira-Flow, and (5) Beautiful-Flow. Half the teeth in each group were thermocycled. The specimens were dyed with 1 per cent methylene blue for 24 hours to determine the percentage of microleakage into the enamel–adhesive and adhesive–bracket interfaces using image analysis equipment. Data were analysed using the Kruskal–Wallis and Mann–Whitney U-tests (P < 0.05), applying Bonferroni correction when required (P < 0.005). Without thermocycling, microleakage at the enamel–adhesive interface was significantly greater for Admira-Flow than for X-Flow (P < 0.005). At the adhesive–bracket interface, there were no significant differences (P > .005). After thermocycling, microleakage of Beautiful-Flow at the enamel–adhesive interface was significantly less than for the other materials tested (P < .005), while at the adhesive–bracket interface, Admira-Flow and X-Flow showed significantly more microleakage than Beautiful-Flow and Transbond XT (P < 0.005). Analysis of the effect of thermocycling on each material showed that microleakage increased significantly at the enamel–adhesive interface with Transbond XT (P < 0.05), decreased with Beautiful-Flow (P < 0.05), increased significantly at both interfaces with X-Flow, but not to a statistically significant level with Dyract-Flow and Admira-Flow (P > 0.05). The giomer, Beautiful-Flow, demonstrated the best performance after thermocycling, while composite resins and, in particular, the flowables showed a poorer performance.es
dc.formatapplication/pdfes
dc.format.extent6es
dc.identifier.citationEuropean Journal of Orthodontics, 31 Mar 2009, 31(4):390-396
dc.identifier.doihttps://doi.org/10.1093/ejo/cjn126
dc.identifier.issnPrint: 0141-5387
dc.identifier.issnElectronic: 1460-2210
dc.identifier.urihttp://hdl.handle.net/10201/142705
dc.languageenges
dc.publisherOxford University Presses
dc.relationSin financiación externa a la Universidades
dc.rightsinfo:eu-repo/semantics/embargoedAccesses
dc.subjectAdhesiveses
dc.subjectCattlees
dc.subjectComposite resinses
dc.subjectDental enameles
dc.subjectIncisorses
dc.subjectmethylene bluees
dc.subjectTeethes
dc.subjectFluid flowes
dc.titleMicroleakage beneath brackets bonded with flowable materials: effect of thermocyclinges
dc.typeinfo:eu-repo/semantics/articlees
dspace.entity.typePublicationes
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
cjn126.pdf
Size:
280.64 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.26 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections