Publication:
Evaluation of endovenous sedation using BIS monitoring in dentistry. A systematic review

dc.contributor.authorLozano Carrascal, Naroa
dc.contributor.authorPérez García, Silvia
dc.contributor.authorRuiz Roca, Juan Antonio
dc.contributor.authorLópez Jornet, María Pía
dc.contributor.authorGargallo Albiol, Jordi
dc.contributor.departmentDermatología, Estomatología, Radiología y Medicina Física
dc.contributor.otherFacultades de la UMU::Facultad de Medicina
dc.date.accessioned2026-03-24T11:51:32Z
dc.date.available2026-03-24T11:51:32Z
dc.date.copyright© Medicina Oral S. L.
dc.date.issued2020-07-01
dc.description.abstractBackground: The aim of the present review was evaluate the utility and validity of the Bispectral Index (BIS) in dental treatment carried out under endovenous sedation, and compare its efficacy with clinical sedation scales.Material and Methods: Electronic and manual literature searches were conducted by two independent reviewers for articles published up to April 2017 in several databases, including Medline and Cochrane Library.Results: Sixteen articles met the inclusion criteria. A correlation was identified between BIS and clinical sedation scales. A BIS range between 75 and 84 showed a high probability of corresponding to an Observer’s Assessment of Alertness and Sedation Scale (OAA/S) value of 3; a scored 3 on the Ramsay scale corresponds around 85 on the BIS; while BIS values between 57 and 64 corresponded to a University of Michigan Sedation Scale value of 3. BIS monitoring provides continuous measurement of the patient’s hypnotic state or state of consciousness, awareness, and recall. It proved impossible to perform an analysis of statistical data drawn from the studies reviewed due to the disparity of inclusion criteria among the works.Conclusions: BIS for sedation monitoring might make possible to evaluate sedation levels objectively in real time, reducing the dose of the sedative required, increasing safety, and minimizing secondary effects.
dc.formatapplication/pdf
dc.format.extent10
dc.identifier.citationMed Oral Patol Oral Cir Bucal, 2020 Jul 1;25 (4):e439-48
dc.identifier.doihttps://doi.org/10.4317/medoral.22884
dc.identifier.eissn1698-6946
dc.identifier.issn1698-4447
dc.identifier.urihttp://hdl.handle.net/10201/222621
dc.languageeng
dc.publisherMedicina Oral, S.L.
dc.relationSin financiación externa a la Universidad
dc.relation.publisherversionhttps://www.medoraljced.com/medoral/revista/2020/July/25/
dc.rights.accessRightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectBIS monitoring
dc.subjectIntravenous sedation
dc.subjectDental treatment
dc.subjectAnesthetics
dc.subjectBispectral analysis
dc.subject.odsNo relacionado con ningún objetivo de desarrollo sostenible
dc.titleEvaluation of endovenous sedation using BIS monitoring in dentistry. A systematic review
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublicationes
relation.isAuthorOfPublicatione24de175-ae66-43d3-adbd-c15f9022e2b6
relation.isAuthorOfPublication4f429718-4d7c-4637-a758-1f1024672669
relation.isAuthorOfPublication.latestForDiscoverye24de175-ae66-43d3-adbd-c15f9022e2b6
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
articulo 4.pdf
Size:
1.09 MB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.37 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections