Publication:
Índice de perfusión en una reanimación con riesgo biológico, como medida de mala tolerancia fisiológica

dc.contributor.authorMartín Rodríguez, Francisco
dc.contributor.authorMartín Conty, José Luis
dc.contributor.authorArnillas Gómez, Pedro
dc.contributor.authorGutiérrez Sevilla, José Ángel
dc.contributor.authorCastro Villamor, Miguel Ángel
dc.contributor.authorCasado Vicente, Verónica
dc.date.accessioned2019-01-15T14:44:15Z
dc.date.available2019-01-15T14:44:15Z
dc.date.issued2019
dc.description.abstractIntroducción:Realizar de una forma adecuada una reanimación cardiopulmonar precisa unos conocimientos técnicos y unas mínimas condiciones físicas. Realizar esta reanimación un equipo de protección individual frente a riesgos biológicos nivel D colocado aumenta el sobresfuerzo al que se ven sometidos los reanimadores.El objetivo de este estudio es comprobar la existencia de un patrón de mala tolerancia fisiológica al uso de los equipos de protección nivel D, categoría 4-5-6B para la actuación en incidentes con riesgo biológico objetivado mediante la medición del índice de perfusión antes y después de una reanimación simulada.Material y métodos:Se ha realizado un estudio cuasiexperimental no controlado sobre 96 voluntarios elegidos mediante un muestreo aleatorio estratificado por sexo, nivel de formación y categoría profesional, estudiantes de Medicina y Enfermería y profesionales Médicos y Enfermeros. Se realizó una toma del índice de perfusión antes de realizar la reanimación y otra después de la reanimación simulada.Resultados:Un 15% de los voluntarios presentaron un índice de perfusión posterior más bajo al basal, lo que se traduce en una situación de vasoconstricción periférica después de la realización del ejercicio físico que supuso el caso clínico, cuando lo esperable era una vasodilatación para aumentar la perfusión. Conclusiones: Extrapolando estos datos, podemos concluir que, en la muestra de estudio que nos ocupa, los voluntarios que presentan menos índice de perfusión al finalizar que al comenzar no toleran bien el esfuerzo que supone el caso clínico.es
dc.description.abstractABSTRACT: Introduction: Perform a cardiopulmonary resuscitation requires technical knowledge and minimal physical conditions. Perform this resuscitation a team of individual protection against biological risks level D placed increases the overexertionthat encourage rescuers are subjected.The objective of this study is to prove the existence of a pattern of poor physiological tolerance to the use of personal protective equipment level D, category 4-5-6B for action in incidents with biological risk objectified by measuring the perfusion index before and after a simulated resuscitation.Material and methods:We have performed a quasiexperimental not controlled on 96 volunteers chosen through a random sampling, stratified by sex, level of education and professional category, medical and nursing students and professionals doctors and nurses.A decision of the perfusion index before performing the resuscitation and other simulated after resuscitation.Results:A 15% of the volunteers presented a perfusion index lower back to baseline, which translates into a situation of peripheral vasoconstriction after the completion of the physical exercise that involved the clinical case, when expected was a vasodilatation to Increase perfusion.Conclussion:Extrapolating these data, we can conclude that, in the sample for the study, the volunteers who have less perfusion index at the end of that at the beginning do not tolerate well the effort involved in the case.es
dc.formatapplication/pdfes
dc.format.extent14es
dc.identifier.citationEnfermería global, vol. 18, n.º 1 (2019)
dc.identifier.issn1695-6141
dc.identifier.urihttp://hdl.handle.net/10201/66460
dc.languagespaes
dc.languageenges
dc.publisherMurcia: Servicio de Publicaciones de la Universidad de Murciaes
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.subjectTolerancia fisiológicaes
dc.subjectExposición a agentes biológicoses
dc.subjectPhysiological tolerancees
dc.subjectExposure to biological agentses
dc.subject.otherCDU::6 - Ciencias aplicadas::61 - Medicina::614 - Higiene y salud pública. Contaminación. Prevención de accidentes. Enfermeríaes
dc.titleÍndice de perfusión en una reanimación con riesgo biológico, como medida de mala tolerancia fisiológicaes
dc.title.alternativePerfusion index in a resuscitation with biological risk, as a measure of poor physiological tolerancees
dc.typeinfo:eu-repo/semantics/articlees
dspace.entity.typePublicationes
Files
Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
322211-Texto del artículo-1203331-1-10-20181231.pdf
Size:
352.91 KB
Format:
Adobe Portable Document Format
Description:
Español
Loading...
Thumbnail Image
Name:
322211-Texto del artículo-1203341-1-10-20181231.pdf
Size:
370.96 KB
Format:
Adobe Portable Document Format
Description:
English
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.39 KB
Format:
Item-specific license agreed upon to submission
Description: