Publication:
Fallo técnico en el implante de anillo Geoform® durante anuloplastia hipercorrectora: a propósito de un caso

dc.contributor.authorParedes, Federico
dc.contributor.authorMartín, Elio
dc.contributor.authorHornero, Fernando
dc.contributor.authorGil, Oscar
dc.contributor.authorGarcía Fuster, Rafael
dc.contributor.authorCánovas López, Sergio
dc.contributor.authorMartínez León, Juan
dc.contributor.departmentCirugía, Pediatría y Obstetricia y Ginecología
dc.date.accessioned2024-07-19T10:44:14Z
dc.date.available2024-07-19T10:44:14Z
dc.date.issued2013-07
dc.description© 2013 Sociedad Española de Cirugía Torácica-Cardiovascular. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/ This document is the Published version of a Published Work that appeared in final form in Cirugía Cardiovascular. To access the final edited and published work see https://doi.org/10.1016/j.circv.2013.04.002
dc.description.abstractLa insuficiencia mitral funcional comúnmente va asociada a la miocardiopatía dilatada, y su corrección se basa habitualmente en realizar una anuloplastia mediante el implante de un anillo rígido. Presentamos un caso de insuficiencia mitral severa en el contexto de una miocardiopatía dilatada que fue corregida mediante el implante de un anillo Geoform® con buen resultado postoperatorio inmediato pero con fracaso tardío de la técnica por dehiscencia de la prótesis anular y fallo de la anuloplastia que obligó a una reintervención e implante de una prótesis valvular mecánica para la solución definitiva del problema.--------------------------es
dc.description.abstractFunctional mitral regurgitation often is associated with dilated cardiomyopathy, or left ventricular remodeling. Surgical repair result commonly in an annuloplasty ring. We present a case of severe mitral regurgitation due to dilated cardiomyopathy treated with implant of Geoform® annuloplasty ring, with a good immediate outcome, and a successive failure of the annuloplasty due to dehiscence of the ring and requirement of a mitral valve replacement.es
dc.formatapplication/pdfes
dc.format.extent3es
dc.identifier.citationCirugía Cardiovascular, 2013, Vol. 20, Issue 3, pp. 153-155
dc.identifier.doihttps://doi.org/10.1016/j.circv.2013.04.002
dc.identifier.issnElectronic: 1134-0096
dc.identifier.urihttp://hdl.handle.net/10201/143257
dc.languagespaes
dc.publisherElsevier
dc.relationSin financiación externa a la Universidades
dc.relation.publisherversionhttps://www.sciencedirect.com/science/article/pii/S1134009613000041?via%3Dihub#sec0020
dc.rightsinfo:eu-repo/semantics/openAccesses
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.subjectRegurgitación mitrales
dc.subjectAnuloplastia hipercorrectoraes
dc.subjectMiocardiopatía funcionales
dc.subjectMitral regurgitationes
dc.subjectAnnuloplasty hyper-correctives
dc.subjectFunctional cardiomyopathyes
dc.titleFallo técnico en el implante de anillo Geoform® durante anuloplastia hipercorrectora: a propósito de un casoes
dc.title.alternativeTechnical failure in the implant of the Geoform® ring during an hyper-corrective annuloplasty: to purpose of a casees
dc.typeinfo:eu-repo/semantics/articlees
dspace.entity.typePublicationes
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
1-s2.0-S1134009613000041-main.pdf
Size:
412.78 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
2.26 KB
Format:
Item-specific license agreed upon to submission
Description:
Collections