Browsing by Subject "Chemiluminescence"
Now showing 1 - 2 of 2
Results Per Page
Sort Options
- PublicationOpen AccessChemiluminescence: a sensitive detection system in in situ hybridization(F. Hernández y Juan F. Madrid. Universidad de Murcia. Departamento de Biología Celular e Histología, 1998) Musiani, M.; Pasini, P.; Zerbini, M.; Roda, A.; Gentilomi, G.; Gallinella, G.; Venturoli, S.; Manaresi, E.Chemiluminescence is the light emission produced by a chemical reaction in which chemically excited molecules decay to the ground state. The phenomenon is utilized in various analytical techniques in which small amounts of analytes or enzymes can be detected and quantified by measurement of the light emitted by bio- or chemiluminescent reactions. Recently chemiluminescence has been proposed as a valid alternative to radioactive or colorimetric methods in in situ hybridization assays, in which target nucleic acids are localized by labeled probes inside individual cells with the preservation of cell morphology. Chemi-luminescence in situ hybridization is performed using probes that are detected using enzymes with their appropriate chemiluminescent substrates. The luminescent signal from the hybrid formation is detected, analysed and measured with a high performance low light level imaging apparatus connected to an optical microscope and to a personal computer for quantitative image analysis. Generally, the instrumental system to detect positive signals after in situ hybridization operates in three steps: firstly tissue structures and cells are recorded in transmitted light then the luminescent signal is measured with an optimized photon accumulation; and then, after a computer elaboration of the luminescent signal with pseudocolors corresponding to the light intensity, an overlay of the two images on the screen provided by the transmitted light and by the luminescent signal allows the spatial distribution of the labeled probe to be localized and evaluated. The main advantages of chemiluminescence in situ hybridization are mainly the sensitivity, the quantifi-cation of the data, the objectivity of the evaluation and the digital imaging of the results. The chemiluminescence in situ hybridization assay, which can be applied to cell smears, archival frozen and paraffin embedded tissue samples, can be a useful tool for a sensitive and specific diagnosis of viral infections and for the detection and study of specific genic sequences inside the cells. The use of the chemi-luminescent in situ hybridization assay is also promising for an estimation and quantification of nucleic acids present in tissue samples or cellular smears and for imaging gene expression in cells.
- PublicationOpen AccessStudy of the uncertainty in NO2 chemiluminescence measurements due to the NO–O3 reaction in sampling lines(Springer, 2011-03) Doval Miñarro, Marta; González Ferradás, Enrique; Barberá Rico, Jonathan; Díaz Alonso, Fernando; Marzal Martínez, Francisco J.; Romero Trigueros, Cristina; Ingeniería QuímicaIntroduction The change in light intensity that takes place when an ambient air sample is drawn into the detection chamber of a chemiluminescence monitor generates changes in the concentrations of several species, such as NO2, NO and O3. Although this phenomenon has been known for several decades, there is still no commonly accepted approach on when or how to correct for it in NO2 and O3 readings. Discussion In this work, we have assessed the expanded uncertainty of two chemiluminescence NO x analysers commercially available according to EN 14211:2005, with the aim of establishing the maximum allowable standard uncertainty due to the reaction between NO and O3 in the sampling system. Conclusion Although this maximum allowable uncertainty cannot be a universal value—as it will depend on the performance of each analyser—our results have led us to propose the conservative value of 2%. We have also proposed a methodology for improving data quality which could be easily implemented by those responsible for air quality data validation.